According to Consumer, Building and Occupational Services Newsletter - August 2025, CBOS August Newsletter
The most common defect to electrical residential installations is the inadequate fire protection to switchboards.
FXN Sticker
According to Consumer, Building and Occupational Services Newsletter - August 2025, CBOS August Newsletter
The most common defect to electrical residential installations is the inadequate fire protection to switchboards. AS/NZS3000:2018 clause 2.10.7 – prescribes the fire protective measures to prevent the spread of fire from within the switchboards into the building, cavities and conduits. Notes provided under 2.10.7 provide guidance on how this can be achieved.
NOTES:
1 See also Clause 2.10.2.5(h) regarding restricted location of switchboards in or near egress paths or fire exits and Clause 3.9.9 regarding requirements to prevent the spread of fire.
2 There is a very high risk that wiring enclosures, especially those that enter at the top or sides of a switchboard, will contribute to the spread of fire and for this reason care needs to be taken to ensure that these wiring systems are provided with close-fitting entries. In some cases, internal sealing should be provided.
3 An opening with less than 5 mm diameter of free space is considered to be a close fit. Therefore, any opening of 5 mm diameter or greater requires sealing with a fire-retardant sealant.
4 Wiring enclosures, such as conduits, having an internal free space of greater than 5 mm diameter also require sealing to stop any draft effect that could allow the spread of fire.
BCAi Solutions is pleased to present FireXNull as an active extinguisher system using nano technology through either the “sticker” or “rope” applications. BCAi is the approved distributor and technical engineering partner (BCA Engineers) for this product in Australia, Singapore and Malaysia.
Refer to FireXNull Products: Proactive Fire Prevention Solutions
If you would like to provide additional fire protection measures over and above the requirements of AS/NZS3000-2018 then we would be pleased to assist, please contact .
FXN Sticker
Attach the appropriately sized FXN Sticker to the interior top of the device for adequate fire extinguishing capacity.
FXN Sticker
Automatic Fire Safety Solution for Enclosures
The FXN Sticker series provides an innovative, cost-effective fire suppression solution designed for electrical enclosures of all sizes. Powered by advanced nanotechnology, each FXN Sticker is heat-sensitive and activates automatically at 120±5°C (248±9°F), suppressing early-stage fires instantly with an eco-friendly, residue-free clean agent. Reliable and maintenance-free, this solution is perfect for safeguarding high-risk environments housing valuable equipment.
Benefits and Features
FXN Sticker Applications
FXN Stickers are designed for enclosures up to 2.3 cubic feet (65 liters), making them ideal for use in:
- Electrical enclosures
- Data centers and server rooms
- Marine and aerospace systems
- Industrial machinery and control panels
- Hospitals and medical equipment
The compact size and efficiency ensure dependable fire suppression at the early stages in critical environments.
FXN Sticker Compatibility for Cabinet Sizes
| Model No. | Sticker Size W x L x T (inches) | Sticker Size W x L x T (mm) | Cabinet Volume (ft³) | Cabinet Volume (L) |
|---|---|---|---|---|
| FXN-S20 | 3.94 x 1.57 x 0.04 | 100 x 40 x 1 | 0.7 | 20 |
| FXN-S30 | 3.94 x 3.94 x 0.04 | 100 x 100 x 1 | 1 | 30 |
| FXN-S50 | 5.91 x 3.94 x 0.04 | 150 x 100 x 1 | 1.8 | 50 |
| FXN-S65 | 7.87 x 3.94 x 0.04 | 200 x 100 x 1 | 2.3 | 65 |
FXN Sticker: Fire Suppression in Action
Watch our demo video: one cabinet with the FXN Sticker extinguishes a fire in just 18 seconds, while the unprotected cabinet burns on.
How It Works
The FXN Sticker utilizes a fire suppression mechanism that activates at 120°C (248°F). Upon reaching this temperature, the sticker releases a clean, non-residue fire-suppressing agent. This agent rapidly vaporizes, absorbing heat and effectively extinguishing the fire without leaving residue or causing damage.
FXN Sticker Installation Manual

1. Environmental Safety
- Ensure the electrical enclosure is completely safe to access and the electrical power to the enclosure is disconnected before installing the FXN Sticker.
- Do not place the FXN Sticker on a hot surface or in an environment where the ambient temperature exceeds 120±5°C (248±9°F).
2. Surface Cleaning
- Clean the ceiling surface.
- Ensure the surface is dry and free of dust, grease, contaminants, and lubricants.
- Use a lint-free cloth to wipe the surface clean.
3. Adhesive Backing Removal
- Peel the protective paper off the adhesive side of the sticker, being careful not to touch the adhesive side.
- Position the sticker on the desired and prepared surface inside the ceiling of the enclosure.
4. Sticker Positioning
- Starting from the center, press the sticker onto the surface and smooth it outwards to remove any air bubbles.
- Firmly press the sticker onto the surface, ensuring full adhesion.
5. Final Steps
- Labeling: Ensure you label the installation date with a 5-year shelf life (expiration).
- Replace the sticker after 5 years or after activation.